Chapter 4 – DICOM Objects
In chapter 3 we’ve learned about DICOM elements. Every element is one piece of typed data with a pre defined, well specified meaning. There are thousands of DICOM elements (See chapter 6 of the standard) from the very basic attributes of patient name and birth date to the most esoteric uses of 3D surface vortices. In this chapter we’re going to collect elements into image object that is called Secondary Capture Image.
The guys at DICOM did a lot of very good work and created well defined classes for a very detailed Data Model. This is why I always advise to dig in the DICOM standard before designing your imaging device software because there’s a very good chance that the DICOM technical committees already did the work for you and you can save a lot of expansive design time this way.
In a way DICOM objects definitions are similar to object oriented programming. I prefer though the analog to interfaces specifications. The motivation to adhere to a standard is to enable interoperability. By detailing information object definitions (IOD’s) DICOM enables us to exchange virtual objects between applications without knowing in advance anything about the application we are going to interface with.
In this chapter I'm going to complete chapter’s 3 examples by adding elements to the object until it’s a valid Secondary Capture Image according to the DICOM standard. Secondary Capture Image is the simplest DICOM image object. Secondary Captures is not related to any specific device. It has the very basic set of elements that a DICOM application needs in order to display and archive a DICOM image properly.